CAUTION
SHOCK HAZARD
Live electrical circuits may
be exposed while performing
these procedures.
These procedures are to
be performed by qualied
technical personnel only.
ERROR DETECTION
13
The 1016BVM brewer is designed to perform a continuous internal
diagnosis, and to signal faults by ashing all the lights. In fault
mode, warmers, heating element and water ll solenoid are turned
“off”, and most keypad functions are disabled.
Error detection (all lights ashing) will occur under two conditions:
Anytime a temperature in excess of 214ºF is detected.
Temperature does not change by at least 2ºF within 4 minutes
of tank heater being energized (HEAT light on).
To reset the brewer after the fault has been corrected, press and
hold the CANCEL key for 3 seconds, or disconnect the brewer from
electrical power for three seconds.
•
•
912 p/n 2M-75936 Owners Manual 1016BVM Coffee Brewer
912 p/n 2M-75936 Owners Manual 1016BVM Coffee Brewer
WHAT TO CHECK DESCRIPTION CORRECTIVE ACTION
Has the water tank been
properly lled?
On initial startup, an attempt to heat a dry tank
will be detected as too high a temperature or
insufcient temp rise, or will trip the high limit.
Tank must be properly lled as detailed on
page 6. Check hi-limit (see below)
Has hi-limit safety thermostat
tripped off?
Brewer may have been started without water
in the tank, or the temp control thermostat may
require adjustment.
Access hi-limit by removing front panel. Hi-
limit is on the left side of the tank. Use an
insulated tool to push the red button in until it
“clicks” and stays. Reset per above.
Check control board and temp
probe.
Brewer will go into error mode immediately
if either the control board or temp probe is
defective. Temp probe electrical resistance
is approximately 30KWat room temp, and
2KW at boiling. Replace temp probe if less
than 1KW
Reset by holding the CANCEL key for
3 seconds. If lights continue to ash:
Disconnect temp probe from control board.
a. If lights continue to ash, unplug brewer
and replace control board.
b. If lights stop ashing, unplug brewer and
replace temp probe.
Check power board and
heating element.
Brewer will go into error mode 4 minutes after
energizing the heating element if insufcient
heat rise is detected. The heating element
is energized by an electronic power board,
and protected by the hi-limit safety. Heating
element should receive full line voltage (i.e.
120V, 208V or 240V). Be sure the hi-limit
safety is reset.
Reset by holding the CANCEL key for 3
seconds. If lights resume ashing after
4 minutes: Check the voltage across the
heating element terminals:
a. If no voltage is present, unplug brewer and
replace power board.
b. If proper voltage is present, nplug brewer
and replace tank heating element.
Is the brew temperature
properly adjusted?
The brewer may occasionally go into error
mode if the brew temperature is set too high.
See page 17 for temperature
adjustment procedure.