10 Sunnen Drive
St. Louis, MO 63143
telephone: 888-356-5362
fax: 314-781-2714
www.wellsbloomfield.com
BLOOMFIELD INDUSTRIES
p/n 2M-75872 Rev. H M642 100811
642
OWNERS MANUAL
for
E. B. C.™
Electronic
Brew
Control ™
AIRPOT AND
THERMAL SERVER
COFFEE BREWERS
MODELS
1080
1082 1082XL
1086 1088
Includes:
Installation
Use & Care
Servicing Instructions
Model 1082 Brewer
with optional
7752 Airpot
E.B.C.™ brewers are protected under
U. S. Patent # 5, 704,275
Other U. S. and Canadian patents pending.
Vista de pagina 0
1 2 3 4 5 6 ... 31 32

Indice de contenidos

Pagina 1 - Control ™

10 Sunnen DriveSt. Louis, MO 63143telephone: 888-356-5362fax: 314-781-2714www.wellsbloomfield.comBLOOMFIELD INDUSTRIES p/n 2M-75872 Rev. H

Pagina 2 - WARRANTY STATEMENT

8OPERATION (continued)ELECTRONIC FEATURESEnergizing the BrewerWhen electric power is applied to the unit, all the lights will ash four times and four

Pagina 3 - APPLICABILITY

OPERATION (continued)Quality Timer is normally set for 30 minutes. It can be set for 20 minutes by moving a jumper on the controller. See page 19.Af

Pagina 4

BREWING COFFEECAUTION: BURN HAZARDExposed surfaces of the brewer, brew chamber and airpot or server may be HOT to the touch, and can cause serious b

Pagina 5

CLEANING INSTRUCTIONS11PROCEDURE: Clean Coffee BrewerPRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool.FREQUENCY: Daily

Pagina 6 - INSTALLATION INSTRUCTIONS

TROUBLESHOOTING SUGGESTIONS12SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDYWater won’t heatBrewer unplugged or circuit breaker trippedCheck power supply cord

Pagina 7

WARNING:SHOCK HAZARD Live electrical circuits may be exposed while performing these procedures. These procedures are to be performed by qualie

Pagina 8 - OPERATION

SERVICING INSTRUCTIONSWARNING:SHOCK HAZARD Opening access panels or removing warmer plates on this brew may expose uninsulated electrical componen

Pagina 9 - WATER FLOW

SERVICING INSTRUCTIONS (continued)TEMPERATURE ADJUSTMENTUnplug power cord or turn circuit breaker OFF. Remove top panel. Remove button plug from fro

Pagina 10 - OPERATION (continued)

SERVICING INSTRUCTIONS (continued)IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. owing pressure. If water pressure exceeds this v

Pagina 11

SERVICING INSTRUCTIONS (continued)17REPLACE SOLENOIDUnplug power cord. Turn OFF and disconnect water supply from brewer inlet tting.Remove front pan

Pagina 12 - CAUTION:

NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the f

Pagina 13 - CLEANING INSTRUCTIONS

REPLACE HOT WATER FAUCET COIL(Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF.)Remove tank lid assembly per

Pagina 14 - TROUBLESHOOTING SUGGESTIONS

SERVICING INSTRUCTIONS (continued)19Fig. 19Keypad Ribbon Cable Hook-UpSET CONTROLLER JUMPERSPlacing the jumper across Q1 sets

Pagina 15 - WARNING:

CAUTION:CHEMICAL BURN HAZARDDeliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure.Never siphon delimin

Pagina 16 - SERVICING INSTRUCTIONS

NOTES:21642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual

Pagina 17

EXPLODED VIEW & PARTS LISTHOT WATER TANK ASSEMBLY22HOT WATER TANK ASSEMBLY642 p/n 2M-75872 1080 1082 1086 1088 Owmers ManualITEM PART NO. DESCRI

Pagina 18

ELECTRICAL COMPONENTSEXPLODED VIEW & PARTS LIST (continued)23ITEM PART NO. DESCRIPTION USED ON30 2E-72936 Switch, Rocker 125/250V 1086, 108831 2C-

Pagina 19

EXPLODED VIEW & PARTS LIST (continued)INTERNAL PLUMBING COMPONENTS24642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual642 p/n 2M-75872 1080 10

Pagina 20

642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual642 p/n 2M-75872 1080 1082 1086 1088 Owmers ManualEXPLODED VIEW & PARTS LIST (continued)CABI

Pagina 21

WIRING DIAGRAM26E.B.C.™ BREWERMODEL VOLTS WATTS AMPS1080 120 1800 151082 120 1800 151080CA 120 1500 121082CA 120 1500 12642 p/n 2M-75872 1080 1082 1

Pagina 22

642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual642 p/n 2M-75872 1080 1082 1086 1088 Owmers ManualWIRING DIAGRAM (continued)27MODEL VOLTS WATTS

Pagina 23

TABLE OF CONTENTSSPECIFICATIONSThank You for purchasing this Wells Bloomeld appliance.Proper installation, professional operation and consistentmaint

Pagina 24

NOTES28642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual

Pagina 25 - NEW-STYLE

NOTES29642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual

Pagina 26 - INTERNAL PLUMBING COMPONENTS

10 Sunnen Drive, St. Louis, MO 63143telephone: 888-356-5362 fax: 314-781-2714www.wellsbloomfield.com

Pagina 27 - CABINET COMPONENTS

FEATURES AND OPERATING CONTROLSFig. 1 Features & Operating Controls2IL1726642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual642 p/n 2M-75872

Pagina 28 - E.B.C.™ BREWER

PRECAUTIONS AND GENERAL INFORMATIONWARNING: ELECTRIC SHOCK HAZARDAll servicing requiring access to non-insulated components must be performed by qual

Pagina 29 - WIRING DIAGRAM (continued)

642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual642 p/n 2M-75872 1080 1082 1086 1088 Owmers ManualINSTALLATION INSTRUCTIONSREAD THIS CAREFULLY B

Pagina 30

642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual642 p/n 2M-75872 1080 1082 1086 1088 Owmers ManualINSTALLATION INSTRUCTIONS (continued)NOTE: Th

Pagina 31

OPERATION6Fig. 4 Brewer Operation DiagramSTART-UP For initial start-up, or if the brewer has not been used for an extended period of time:

Pagina 32

OPERATION (continued)7WATER HEATERWater temperature is sensed by an electronic water temperature probe inserted into the water tank. This temperature