All LEDs flashing: GENERAL FAULT
Possible causes are a shorted temperature probe, an over-temperature condition,
or controller did not detect at least 2ºF temperature rise within 4 minutes.
Press CANCEL for 6 seconds to reset after a general fault.
IMPORTANT: Be sure brewer has sufficient inlet water volume. Low volume will
allow water in tank to boil, resulting in possible over-temperature shut-down.
Allow unit to cool and complete tank fill procedure before attempting a reset.
TEST 1: Disconnect probe from control board and press CANCEL for 6 sec. to reset.
unit resets, probe is defective. Replace probe p/n 83644. Be sure to replace seal
washer p/n 83731 at the same time.
unit does NOT reset, or returns to fault within 4 minutes, proceed to next test.
TEST 2: Connect a known good temperature probe to control board. Reset unit.
unit will not reset, replace control board p/n 83635.
HEAT LED lights, but unit returns to fault, proceed to next test.
.
TEST 3: Check for line voltage at heating element terminals.
voltage is present, replace heating element p/n 8716-1. Also, be sure to replace
gaskets p/n 8043-30.
voltage is NOT present, proceed to next test.
TEST 4: Be sure hi-limit thermostat is reset. Check for line voltage at power board
terminals LINE IN and NEUTRAL IN.
voltage is present, replace power board p/n 83636.
page2of8
BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDE
DIAGNOSTICS - FLASHING LIGHTS AND BEEPING ALERTS
IF
IF
IF
IF
IF
IF
IF
CAUTION
The following procedure exposes live electric circuits.
Use due care when working around electricity.
CAUTION
The following procedure exposes live electric circuits.
Use due care when working around electricity.
Service Bulletin 107.002