PRINTED IN UNITED STATES OF AMERICA p/n 73902 Rev. F ECN-12817
PROGRAMMING FEATURES AND OPTIONS 1. View Water Temperature in Tank: To view the water temperature on the screen, E-Max T™ brewer must be ON
8. Clock A. Time – Battery Backup. The E-Max T™ has a battery backup system which will maintain the proper time during power
OPERATION (continued) 10 12. View Filter Statistics: To view filter statistics, turn the brewer off. Press and hold the 1st key (Brew), an
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow bre
FUNCTION 1. Water enters at the inlet fitting of the fill solenoid (32). The solenoid admits water via a command from the controller.
SERVICING INSTRUCTIONS — PLUMBING (continued) 13 ITEM DESCRIPTION PART N0. USED ON 1 2 ASSEMBLY, WATER TANK (120V) 83500 2030 6 GASKET, TAN
SERVICING INSTRUCTIONS - ELECTRICAL FUNCTION 1. Pressing the POWER key energizes the unit. The POWER LED will glow whenever the unit is ON. 2. Au
SERVICING INSTRUCTIONS - ELECTRICAL (continued) 15 ITEM DESCRIPTION PART N0. USED ON 3 PROBE, TEMPERATURE 83480 ALL 4 THERMOSTAT, HI-LIMIT SAFETY (1
SERVICING INSTRUCTIONS — DE-LIMING HEATER TANK 1. Disconnect brewer form the electrical supply. Turn off the water supply and disconnect w
TROUBLESHOOTING SUGGESTIONS If the E-Max T™ goes into the error mode as outlined below, it will likely be necessary to reset the brewer in order to te
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the f
E-Max T™ TEST PROGRAM 18 Instructions for testing procedures for the following system components (using the E-Max T™ Built-In Diagnostic): Ele
E-Max T™ TEST PROGRAM (continued) 19 E. LED Test The display should read “Testing LED’s”: Individual LED’s will be tested individually, begi
EXPLODED VIEW & PARTS LIST 20
EXPLODED VIEW & PARTS LIST (continued) 21 ITEM PART # DESCRIPTION QTY 1 8783-1 FAUCET, HOT WATER 1 2 83500 TANK ASSEMBLY, 120V 1 3 83
WIRING DIAGRAMS (continued) 22
NOTES 23
PRINTED IN UNITED STATES OF AMERICA Bloomfield Industries, Inc.Division of Carrier Commercial RefrigerationIn US and CanadaTelephone: 775-689-5700Fax:
TABLE OF CONTENTS SPECIFICATIONS Thank You for purchasing this Bloomfield Industries appliance. Proper installation, professional operation and consi
FEATURES AND OPERATING CONTROLS 2 Features & Operating Controls
WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not o
INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION UNPACKING & INITIAL INSPECTION 1. Unpack the unit. Inspect all
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing codes
OPERATION IMPORTANT: All E-Max T™ brewers are tested and set at the factory. If programming adjust-ments are necessary, refer to the E-Max™ Prog
OPERATION (continued) WARNING: Burn Hazard. This appliance dispenses very hot liquid. Serious bodily injury f