SERVICING
SERVICING INSTRUCTIONS (continued)
6
SV161 SvcManual Electric Char-Broilers
REPLACE INFINITE SWITCH
COUNTERTOP UNITS:
1. Disconnect unit from electric power and allow to cool.
2. Remove control knob. Remove screws holding trim ring to cabinet.
Withdraw trim ring and switch.
3. Note orientation of switch to trim ring. Mark location of wires on
switch. Remove wires from switch. Remove and discard infinite
switch.
4. Mount new switch to trim ring, being careful to maintain proper
orientation. Connect wiring to switch. Remount trim ring and
switch in cabinet.
5. Reconnect to electric power and test for proper operation.
BUILT-IN UNITS:
1. Disconnect unit from electric power and allow to cool.
2. Remove control knob. Remove screws holding control panel to
cabinet. Withdraw control panel and switches.
3. Note orientation of switch on control panel. Mark location of wires
on switch. Remove wires from switch. Remove and discard infinite
switch.
4. Mount new switch to panel, being careful to maintain proper
orientation. Connect wiring to switch. Remount control panel
and switches into cabinet.
5. Reconnect to electric power and test for proper operation.
CAUTION:
HOT SURFACE
Exposed surfaces can be hot
to the touch and may cause
burns.
KNOB
TRIM RING (OR CONTROL PANEL)
INFINITE
SWITCH
P L1
H1
L2
H2
L2
L1
LOAD
INDICATOR
LIGHT