TROUBLESHOOTING SUGGESTIONS
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Will not heat or brew
(no lights)
Brewer not plugged in or circuit
breaker tripped
Reconnect brewer to electric power
Reset circuit breaker
Fuse blown
Check satellite for water saturation
Replace fuse
Will not brew
Satellite is not in proper position
Reinstall satellite. Satellite light should
be on
Brew switch damaged Check. Replace if needed
Timer damaged Check. Replace if needed
Volume selector switch damaged Check. Replace if needed
Satellite connector snap-action switch
damaged
Check. Replace if needed
Brewer fails to heat
Tank heat switch off Turn tank heat switch on
Hi-limit tripped Allow to cool, reset hi-limit
Thermostat out of adjustment or
damaged
Check. Adjust or replace as needed
Satellite receptacle or brewer
connector damaged
Check connectors. Be sure all pins are
in place and tight. Replace if needed
Brewer fails to stop
brewing after STOP
switch pressed
Switch not pressed long enough or
rmly enough
Switch must be pressed rmly for at
least 1 second
Stop Brew switch damaged Check. Replace if needed
Brew solenoid damaged or dirty Check. Clean or replace as needed
Coffee overows
from brew chamber
Too much coffee or too ne a grind
Use proper amount and grind of coffee
grounds per brew
More than 1 lter paper or wrong type
of lter paper used
Use 1 genuine Bloomeld lter paper per
brew
Timer out of adjustment or damaged
Check time. Adjust or replace as
needed
Brew solenoid damaged Check. Replace if needed
Wire rack missing from brew chamber Check. Replace if needed
Insufcient brew
volume
(all volumes)
Low inlet water pressure
Other appliances on water line may be
robbing pressure. Brewer should be on
dedicated water line
Inlet strainer plugged Clean strainer
Timers out of adjustment Adjust time for each brew volume
Timer damaged Check. Replace if needed
Satellite overows
(1-1/2 gal brew only)
Bypass solenoid damaged Check. Replace if needed
16