Pressing the Item key brings the user to the settings for volume #2, #3, and so on until #6. Recall that volumes #1,2 and 3
correspond to the ½ gallon, 1 gallon and 1½ gallon selections for the left satellite, and that volumes #4, 5 and 6 correspond to the ½
gallon, 1 gallon and 1½ gallon selections for the right satellite.
Setting Symmetric Brew Settings
After completing the volume settings for the left batch, or if the left batch settings are skipped, we come to the option:
Set L=R? Y/N Selecting Y will copy all of the left side settings to the right side.
The next menu item is Change R. Vols? which can take you into right side batch settings, that can be programmed different from
left side.
Changing the Timer for Coffee Quality Indication
The coffee quality indicators (satellite LEDs) will turn on once a brew has been completed, and will stay on for a specified amount
of time before flashing. A flashing satellite LED is an indication that the coffee should be re-brewed.
QualityTime: 30m
This time is adjustable from 30 minutes to 180 minutes.
If the satellite is removed or reinstalled, the LED will turn off until another brew of coffee is made.
NOTE: If a brew is cancelled, the Satellite indicator will flash since the amount of time to properly brew was not
correct.
After-Hours Options
The After-Hours mode is intended to increase the temperature range in which to maintain the water. This will reduce the rate in
which the relay contacts will wear out. After hours mode is entered after an adjustable amount of time. First, a menu item is
displayed to enable/disable After-Hours:
After-Hours: On
By default, After-Hours is enabled. After-Hours can be disabled/re-enabled using the (+) or (-) key. If After Hours is Off
(disabled), then the following menu item is skipped when the Item key is pressed, moving on to Timer menu functions. If After-
Hours is enabled, the delay time after the last brew before entering into After-Hours mode is displayed:
Delay Time: 3h
The default delay time is 3 hours, but is adjustable to between 1 hour and 5 hours. Adjusting the
Timer
To save energy and extend component life, a timer is used to select the day and time in which the brewer will automatically shut-
off and restart. It is primarily a management decision on when the brewer will be used. By default, the timer is turned off: