ELECTRICIAN’S INSTALLATION INSTRUCTIONS
WARNING ELECTRICAL SHOCK HAZARD: Brewer must be properly grounded to
prevent possible shock hazard.
D0 NOT assume a plumbing Iine will provide such
a ground.
Electrical shock will cause death or serious Injury.
The unit requires a dedicated power source capable of supplying: 1201240 Volt A.C. 50/60
Hertz, (4) wire, Single Phase, 30 Amp Service for Model SS1-BD and 1201206 Volt A.C. 50/60
Herts, (4) wire, Single Phase, 30 Amp Service for Model SS1-AD.
INITIAL INSTALLATION INSTRUCTIONS..
CAUTION: Initial. Installation should be performed by a qualified Installer or qualified
service technician.
Improper Installation will damage the Brewer and void warranty. .
Electrician’s and Plumber’s Instructions should be followed carefully before proceeding
with initial Installation Instructions.
Be sure all electrical and plumbing connections are secure and leak proof.
DO NOT CONNECT POWER TO UNIT WITH SATELLITES IN PLACE.
With Power Connected, “Bloomfield” will display momentarily and Brewer will “Beep”.
Press Power Switch.
NOTE:
Inlet solenoid will energize and tank will begin to fill. “Filling’ will display.
Fill time for tank is approximately 13 minutes, unit fills tank until water level is 1/8”
above level probe tip.
If tank is not full within 20 minutes, the unit will shut down and
a “NO WATER SENSED” error is displayed.
NOTE:
if a ‘No Water Sensed’ error is displayed, unplug Brewer. See plumber’s installation
instruction.
If plumbing and water pressure is correct, check inlet solenoid for function
and debris.
When tank is filled ,
“Tank Heater’ LED will turn on and “HEATING” is displayed.
Insert Satellites.
Check Satellite alignment and make sure Satellite LEDS are on.
Allow 30 minutes for initial water heat up.
Time will vary with incoming water temperature.
When tank water is up to desired Brew temperature, the “Tank Heater” LED will turn off.
NOTE:
Before brewing and after initial Heat-up, draw water from the Hot Water Faucet until
the inlet Solenoid is actuated. This prevents volume differances to the initial Brew caused
by water expansion.
NOTE:
Brewer will not function unless a Satellite is properly positioned on the Brewer.
3
The Brewer is now ready for use.