PULSE BREW AND PRE-INFUSION (continued)
Pulse Feature Examples DECANTER, THERMAL and AIRPOT MODELS
1. Pre-Infuse Standard 64 oz. Brew. Total valve time of 172 seconds required for 64 oz.
· Init Vlv Time: 20
· Pulse Delay: 30
· Pulse Valve On: 152
· Total Valve: 172
2. Extend Contact Time on Standard 64 oz. Brew. Total valve time of 172 seconds required for
64oz. Extend contact time by 60 seconds by introducing 3 pulse cycles, each with a 20 second
delay.
· Init Vlv Time: 10
· Pulse Delay: 20
· Pulse Valve On: 54
· Total Valve: 172
21
#1 PRE-INFUSION
ON ON
OFF
30 sec.
20 sec.
152 sec.
OFF - DRIP OUT
60 sec.
One Pulse Cycle
0 60 120 180 240 300 360 420 480 540 600
Total Valve 172
Total Delay 30
Drip Out 60
Total Brew 262
#2 EXTENDED CONTACT TIME
ON ON ON ON
OFF
OFF OFF OFF - DRIP OUT
1st pulse
2nd pulse
3rd pulse
0 60 120 180 240 300 360 420 480 540 600
10 sec. 54 sec. 54 sec. 54 sec.
20 sec. 20 sec. 20 sec. 60 sec.
Total Valve 172
Total Delay 60
Drip Out 60
Total Brew 292