2. Extend Contact Time on Standard 3 gal. Brew. Total valve time of 319 seconds required for 128
oz. of water.
Extend contact time by 65 seconds by introducing 4 pulse cycles, each with a 20 second delay.
· Init Vlv Time: 63
· Pulse Delay: 20
· Pulse Valve On: 64
· Total Valve: 319
· Bypass Delay 20
· Bypass Valve 319
3. Prevent Brew Basket Overflow. Total valve time of 319 seconds required for 128 oz. of water.
Extend the delivery over a longer period of time, say 8 minutes to prevent overflow of brew bas-
ket, by having 4 valve delay periods. Initial Valve time is arbitrarily set at 65 seconds. Program
the delay required 136 seconds over 4 pulse cycles, each with a delay of 34 seconds. To calcu-
late the Pulse Valve time: Total Valve Time minus Initial Valve Time divided by 4 pulse cycles.
· Init Vlv Time: 63
· Pulse Delay: 34
· Pulse Valve On: 64
· Total Valve: 319
· Bypass Delay 20
· Bypass Valve 319
23
PULSE BREW AND PRE-INFUSION (continued)
0 60 120 180 240 300 360 420 480 540 600
63 sec
64 sec 64 sec
64 sec 64 sec
60 sec
20 sec 20 sec
20 sec 20 sec
OFF
OFF
OFF OFF OFF
ON
ON
ON
ON
ON
#2 EXTENDED CONTACT TIME
1st Pulse 2nd Pulse 3rd Pulse 4th Pulse Drip Out
Total Valve 319
Total Delay 80
Drip Out 60
Total Brew 459
Total Valve 319
Total Delay 136
Drip Out 60
Total Brew 515
0 60 120 180 240 300 360 420 480 540 600
63 sec
64 sec
64 sec
64 sec 64 sec
60 sec34 sec34 sec
34 sec34 sec
OFF OFF
OFF
OFF
OFF
ON
ON
ON
ON ON
#3 PREVENT BREW BASKET OVERFLO
1st Pulse 4th Pulse3rd Pulse2nd Pulse
Drip Out