TEST PROGRAM – E-Max™(continued)
Tea Brewers Only
Decanter Brewers Only
13. By Pass Valve Off. Press ON/OFF to first turn valve on
then again to turn it off and proceed to next item.
14. Heater Off. Press ON/OFF to turn tank heating element
on, then press ON/OFF to turn it off and proceed to next
item.
13. WP1 Off. Press ON/OFF to turn warming plate 1 (Main)
element on. Press ON/OFF to turn it off and proceed to
next item. (If brewer is set to Thermal the warmer plate
tests will be by- passed.)
14. WP2 Off. Press ON/OFF to turn warming plate 2 (Front)
element on. Press ON/OFF to turn it off and proceed to
next item.
15. WP3 Off. Press ON/OFF to turn warming plate 3 (Rear)
element on. Press ON/OFF to turn it off and proceed to
next item.
16. Probe Test
Screen reads Probes XXX XXX
• The left number determines whether the WATER-sensing
probe is in contact with water. A number of “0” (or close to
0) means that water is in contact with the probe, while a
number of 255 (or close to 255) means water is not in
contact with the probe.
• The right number represents what the TEMPERATURE-
sensing probe reads. The table below is an approximate
correlation between the value and the temperature the
probe is sensing. (Note a number less than 10 would
indicate the probe is not properly connected to the board,
while a number higher than 155 indicate a defective probe.)
Press ON/OFF to proceed to next item.
17. Test Done. Indicates completion, press ON/OFF to reset
controller. The controller should restart with the message
“BLOOMFIELD”, then return to the off mode.
25
Right
Number
≤
10
Probe not
connected
20
25
30
120
125
130
135
140
≥
155
↓
↓
74°F
83°F
92°F
181°F
186°F
191°F
196°F
201°F
Defective
Probe