TEST PROGRAM – E-Max™(continued)
Tea Brewers Only
Decanter Brewers Only
13. By Pass Valve Off. Press ON/OFF to first turn valve on
then again to turn it off and proceed to next item.
14. Heater Off. Press ON/OFF to turn tank heating element
on, then press ON/OFF to turn it off and proceed to next
item.
13. WP1 Off. Press ON/OFF to turn warming plate 1 (Main)
element on. Press ON/OFF to turn it off and proceed to
next item. (If brewer is set to Thermal the warmer plate
tests will be by- passed.)
14. WP2 Off. Press ON/OFF to turn warming plate 2 (Front)
element on. Press ON/OFF to turn it off and proceed to
next item.
15. WP3 Off. Press ON/OFF to turn warming plate 3 (Rear)
element on. Press ON/OFF to turn it off and proceed to
next item.
16. Probe Test
Screen reads Probes XXX XXX
The left number determines whether the WATER-sensing
probe is in contact with water. A number of “0” (or close to
0) means that water is in contact with the probe, while a
number of 255 (or close to 255) means water is not in
contact with the probe.
The right number represents what the TEMPERATURE-
sensing probe reads. The table below is an approximate
correlation between the value and the temperature the
probe is sensing. (Note a number less than 10 would
indicate the probe is not properly connected to the board,
while a number higher than 155 indicate a defective probe.)
Press ON/OFF to proceed to next item.
17. Test Done. Indicates completion, press ON/OFF to reset
controller. The controller should restart with the message
“BLOOMFIELD”, then return to the off mode.
25
Right
Number
10
Probe not
connected
20
25
30
120
125
130
135
140
155
74°F
83°F
92°F
181°F
186°F
191°F
196°F
201°F
Defective
Probe