Vista de pagina 0
10 Sunnen Drive
St. Louis, MO 63143
telephone: 314-678-6336
fax: 314-781-2714
www.bloomfieldworldwide.com
IL2839
p/n 2M-Z18642 Rev.- M664 140624
664
OWNERS MANUAL
for
2790TF-SERIES
DUAL THERMAL
COFFEE BREWERS
with
E-Max
CONTROL
MODEL:
2790TF
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 2790TF Dual Thermal E-Max Brewer
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - St. Louis, MO 63143

10 Sunnen DriveSt. Louis, MO 63143telephone: 314-678-6336fax: 314-781-2714www.bloomfieldworldwide.comIL2839p/n 2M-Z18642 Rev.- M664 140624 6

Pagina 2 - WARRANTY STATEMENT

8664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerOPERATING INSTRUCTIONS (continued)Fig. 4 Operating ControlsFig. 5 Brew BasketCAUTION:Bur

Pagina 3 - TABLE OF CONTENTS

9664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal Brewer9OPERATING INSTRUCTIONS (continued)IL2828WATER LEVEL PROBEVENT (TO BREW HEAD)TEEHOT WATERF

Pagina 4 - CONTROLS

10664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerCLEANING INSTRUCTIONSCAUTION:Burn HazardBrewing and serving temperatures of coffee are ex

Pagina 5 - Drip Tray (optional)

11664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerCLEANING INSTRUCTIONS (continued)PROCEDURE: Clean ThermalsPRECAUTIONS: Drain Thermal

Pagina 6

12664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerPROGRAMMING INSTRUCTIONSFig. 7 Function KeysNEW MENU SETTINGSMenu Program: Press POWER k

Pagina 7 - INSTALLATION INSTRUCTIONS

13664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerPROGRAMMING INSTRUCTIONS (continued)PRECISE BREWINGTEMPERATURE™:The brew cycle will not s

Pagina 8 - WITH SATELLITES IN

14664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerON/OFF – Normal Operation(Non Automatic Timer): To turn the brewer OFF, press the POWER k

Pagina 9 - OPERATING INSTRUCTIONS

15664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerPROGRAMMING (continued) Brew VolumeThe 1st key is the Standard Brew Volume. When a brew

Pagina 10 - CAUTION:

16664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerPROGRAMMING (continued)The factory programming has the After Hours™ mode turned OFF. Whil

Pagina 11 - HOT WATER FAUCET

17664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerTROUBLESHOOTING SUGGESTIONSDESCRIPTION OF PROBLEM POSSIBLE CAUSE SUGGESTED REMEDYNo light

Pagina 12 - Electric Shock

WARRANTY STATEMENTAll equipment manufactured by Bloomeld is warranted against defects in materials and workmanship for the time periods listed in the

Pagina 13 - PROCEDURE: Clean Thermals

18664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerSERVICING INSTRUCTIONSCAUTION - CHEMICAL BURN HAZARDDeliming chemicals are caustic. Wear

Pagina 14 - PROGRAMMING INSTRUCTIONS

19664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerSERVICING INSTRUCTIONS (continued)10. Reinstall tank lid assembly into hot water tank.

Pagina 15 - FEATURES

20664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerEXPLODED VIEW CABINET AND EXTERIOR COMPONENTSSK2790, Rev. -, 6/23/14Model: 2790, E-Ma

Pagina 16 - PROGRAMMING (continued)

21664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerPARTS LIST: 2221 MAIN ASSEMBLYModel: 2790TF E-Max Thermal BrewerFig No. Part Number Qty D

Pagina 17

22664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerEXPLODED VIEW: TANK ASSEMBLY DETAIL ADETAIL ASK2794, Rev. -, 6/23/14Dual Thermal Brewer

Pagina 18

23664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerPARTS LIST: 2221 TANK ASSEMBLY, DETAIL ADetail A: Dual Tank AssyFig. No. Part No Qty Desc

Pagina 19 - TROUBLESHOOTING SUGGESTIONS

24664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerWIRING DIAGRAM: 2790TF2M-Z18614BYPASS VALVERIGHT3POWERSWITCHP12P11P9423222120240V 3000WHT

Pagina 20 - IMPORTANT:

25664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerNOTES

Pagina 21

10 Sunnen Drive, St. Louis, MO 63143telephone: 314-678-6336 fax: 314-781-2714www.bloomfieldworldwide.com

Pagina 22 - SK2790, Rev. -, 6/23/14

1664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerTABLE OF CONTENTSThank You for purchasing this Bloomeld Industries appliance.Proper insta

Pagina 23

2664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerFEATURES AND OPERATING CONTROLSFig 1. E-Max Satellite Brewing System Features & Opera

Pagina 24

3664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerFEATURES AND OPERATING CONTROLS (continued)Brewer Adjustable Legs Brewing Controls

Pagina 25 - Detail A: Dual Tank Assy

4664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerThis appliance is intended for use in commercial establishments only.This appliance is int

Pagina 26 - WIRING DIAGRAM: 2790TF

5664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerINSTALLATION INSTRUCTIONSINSTALL LEGSThe brewer is provided with 4” adjustable legs and ru

Pagina 27

6664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerINSTALLATION INSTRUCTIONS (continued)IMPORTANT:Initial set-up must be performed by a quali

Pagina 28

7664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal BrewerNOTE:If water is not sensed at the water level sensor within 20 minutes: Heater will